TY - JOUR
T1 - Strength Assessment of Trunk Rotator Muscles
T2 - A Multicenter Reliability Study
AU - Rodríguez-Perea, Angela
AU - Morenas Aguilar, María Dolores
AU - Escobar-Molina, Raquel
AU - Martínez-García, Darío
AU - Chirosa Ríos, Ignacio
AU - Jerez-Mayorga, Daniel
AU - Chirosa Ríos, Luis
AU - Janicijevic, Danica
AU - Reyes-Ferrada, Waleska
N1 - Publisher Copyright:
© 2023 by the authors.
PY - 2023/8
Y1 - 2023/8
N2 - Background: Trunk rotator strength plays an important role in sports performance and health. A reliable method to assess these muscles with functional electromechanical dynamometer has not been described. Therefore, the objectives of this paper were (I) to explore the reliability of different strength variables collected in isokinetic and isometric conditions during two trunk rotator exercises, and (II) to determine the relationship of isometric and dynamic strength variables collected in the same exercise. Methods: A repeated measures design was performed to evaluate the reliability of the horizontal cable woodchop (HCW) and low cable woodchop (LCW) exercises. Reliability was assessed using t-tests of paired samples for the effect size, the standard error of measurement, the coefficient of variation (CV) and the intraclass correlation coefficient (ICC). The Pearson’s (r) correlation coefficient was used to explore the association between isometric and isokinetic tests. Results: HCW exercise is more reliable than LCW exercise in assessing trunk rotator muscles. The strength manifestation that should be used is the average strength, and the most reliable evaluation was the HCW at 0.40 m·s−1 concentric (ICC = 0.89; CV = 10.21%) and eccentric (ICC = 0.85; CV = 9.33%) contraction and the dynamic condition that most correlated with the isometric was LWC at 0.50 m·s−1 (r = 0.83; p < 0.01). Conclusion: HCW is a reliable exercise to measure trunk rotator muscles.
AB - Background: Trunk rotator strength plays an important role in sports performance and health. A reliable method to assess these muscles with functional electromechanical dynamometer has not been described. Therefore, the objectives of this paper were (I) to explore the reliability of different strength variables collected in isokinetic and isometric conditions during two trunk rotator exercises, and (II) to determine the relationship of isometric and dynamic strength variables collected in the same exercise. Methods: A repeated measures design was performed to evaluate the reliability of the horizontal cable woodchop (HCW) and low cable woodchop (LCW) exercises. Reliability was assessed using t-tests of paired samples for the effect size, the standard error of measurement, the coefficient of variation (CV) and the intraclass correlation coefficient (ICC). The Pearson’s (r) correlation coefficient was used to explore the association between isometric and isokinetic tests. Results: HCW exercise is more reliable than LCW exercise in assessing trunk rotator muscles. The strength manifestation that should be used is the average strength, and the most reliable evaluation was the HCW at 0.40 m·s−1 concentric (ICC = 0.89; CV = 10.21%) and eccentric (ICC = 0.85; CV = 9.33%) contraction and the dynamic condition that most correlated with the isometric was LWC at 0.50 m·s−1 (r = 0.83; p < 0.01). Conclusion: HCW is a reliable exercise to measure trunk rotator muscles.
KW - core strength
KW - isokinetic
KW - muscle strength dynamometer
KW - reproducibility
KW - testing
UR - http://www.scopus.com/inward/record.url?scp=85169110799&partnerID=8YFLogxK
U2 - 10.3390/healthcare11162331
DO - 10.3390/healthcare11162331
M3 - Article
AN - SCOPUS:85169110799
SN - 2227-9032
VL - 11
JO - Healthcare (Switzerland)
JF - Healthcare (Switzerland)
IS - 16
M1 - 2331
ER -