Performance of Multiplexed XY Resistive Micromegas detectors in a high intensity beam

D. Banerjee, V. Burtsev, A. Chumakov, D. Cooke, E. Depero, A. V. Dermenev, S. V. Donskov, F. Dubinin, R. R. Dusaev, S. Emmenegger, A. Fabich, V. N. Frolov, A. Gardikiotis, S. N. Gninenko, M. Hösgen, A. E. Karneyeu, B. Ketzer, M. M. Kirsanov, I. V. Konorov, V. A. KramarenkoS. V. Kuleshov, E. Levchenko, V. E. Lyubovitskij, V. Lysan, S. Mamon, V. A. Matveev, Yu V. Mikhailov, V. V. Myalkovskiy, V. D. Peshekhonov, D. V. Peshekhonov, V. A. Polyakov, B. Radics, A. Rubbia, V. D. Samoylenko, V. O. Tikhomirov, D. A. Tlisov, A. N. Toropin, B. Vasilishin, G. Vasquez Arenas, P. Ulloa, P. Crivelli

Resultado de la investigación: Contribución a una revistaArtículorevisión exhaustiva

4 Citas (Scopus)

Resumen

© 2017 The Authors We present the performance of multiplexed XY resistive Micromegas detectors tested in the CERN SPS 100 GeV/c electron beam at intensities up to 3.3×105e−∕(s⋅cm2). So far, all studies with multiplexed Micromegas have only been reported for tests with radioactive sources and cosmic rays. The use of multiplexed modules in high intensity environments was not explored due to the effect of ambiguities in the reconstruction of the hit point caused by the multiplexing feature. For the specific mapping and beam intensities analyzed in this work with a multiplexing factor of five, more than 50% level of ambiguity is introduced due to particle pile-up as well as fake clusters due to the mapping feature. Our results prove that by using the additional information of cluster size and integrated charge from the signal clusters induced on the XY strips, the ambiguities can be reduced to a level below 2%. The tested detectors are used in the CERN NA64 experiment for tracking the incoming particles bending in a magnetic field in order to reconstruct their momentum. The average hit detection efficiency of each module was found to be ∼96% at the highest beam intensities. By using four modules a tracking resolution of 1.1% was obtained with ∼85% combined tracking efficiency.
Idioma originalInglés
Páginas (desde-hasta)72-81
Número de páginas10
PublicaciónNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
DOI
EstadoPublicada - 11 feb 2018
Publicado de forma externa

Áreas temáticas de ASJC Scopus

  • Física nuclear y de alta energía

Huella Profundice en los temas de investigación de 'Performance of Multiplexed XY Resistive Micromegas detectors in a high intensity beam'. En conjunto forman una huella única.

Citar esto