TY - JOUR
T1 - Grip power test
T2 - A new valid and reliable method for assessing muscle power in healthy adolescents
AU - Huerta Ojeda, Álvaro
AU - Fontecilla Díaz, Blanca
AU - Yeomans Cabrera, María Mercedes
AU - Jerez-Mayorga, Daniel
PY - 2021
Y1 - 2021
N2 - The assessment of the strength and muscle mass of the hand-finger segment are reliable indicators of health and predictors of cardiometabolic risk in the adult population. However, there are no valid and reliable tests to assess the muscle power of this segment in healthy adolescents. The objective of this study was to determine the validity and inter-day reliability of a grip power test (GripW test) in healthy adolescents. Twenty-one adolescents (15.61 ± 2.20 years old) were part of the study. All participants were instructed to perform a grip with incremental load sets from 1-10 kg as fast as possible. The validity of the GripW test was determined with the load-power curve and linear regression equation. Inter-day reliability considered the coefficient of variation (CV), intra-class correlation coefficient (ICC), and standard error of the mean (SEM). The significance level for all statistical analyses was p < 0.05. The parabola in the load-power curve for both hands showed normality for the GripW test. In addition, the analysis showed a CV = 4.63% and ICC = 1.00 for the right hand, while the left hand showed a CV = 3.23% and ICC = 1.00. The GripW test proved to be valid and reliable for assessing gripping muscle power functionally and unilaterally in healthy adolescents.
AB - The assessment of the strength and muscle mass of the hand-finger segment are reliable indicators of health and predictors of cardiometabolic risk in the adult population. However, there are no valid and reliable tests to assess the muscle power of this segment in healthy adolescents. The objective of this study was to determine the validity and inter-day reliability of a grip power test (GripW test) in healthy adolescents. Twenty-one adolescents (15.61 ± 2.20 years old) were part of the study. All participants were instructed to perform a grip with incremental load sets from 1-10 kg as fast as possible. The validity of the GripW test was determined with the load-power curve and linear regression equation. Inter-day reliability considered the coefficient of variation (CV), intra-class correlation coefficient (ICC), and standard error of the mean (SEM). The significance level for all statistical analyses was p < 0.05. The parabola in the load-power curve for both hands showed normality for the GripW test. In addition, the analysis showed a CV = 4.63% and ICC = 1.00 for the right hand, while the left hand showed a CV = 3.23% and ICC = 1.00. The GripW test proved to be valid and reliable for assessing gripping muscle power functionally and unilaterally in healthy adolescents.
UR - http://www.scopus.com/inward/record.url?scp=85120149043&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0258720
DO - 10.1371/journal.pone.0258720
M3 - Article
C2 - 34669739
AN - SCOPUS:85120149043
SN - 1932-6203
VL - 16
SP - e0258720
JO - PLoS ONE
JF - PLoS ONE
IS - 10
ER -