Direct torque control with reduced switching losses for asymmetric multilevel inverter fed induction motor drives

Samir Kouro, Rafael Bernai, Hernán Miranda, José Rodríguez, Jorge Pontt

Resultado de la investigación: Contribución a los tipos de informe/libroContribución a la conferenciarevisión exhaustiva

19 Citas (Scopus)

Resumen

In this paper a high performance torque and flux control strategy for multilevel inverter fed induction motor drives is presented. The control method is based on Direct Torque Control operating principles. The stator voltage vector reference is computed from the stator flux error imposed by the torque controller. This voltage reference is then generated using an asymmetric cascaded H-bridge multilevel inverter. This inverter provides nearly sinusoidal voltages with very low distortion, using less switching devices. Due to the small dv/dt's, torque ripple is greatly reduced. In addition, the asymmetric multilevel inverter can generate a high and fixed switching frequency output voltages with less switching losses, since only the small power cells of the inverter operate at high switching rate. Therefore a high performance and also efficient torque and flux controller is obtained, enabling a DTC solution for multilevel inverter powered motor drives.

Idioma originalInglés
Título de la publicación alojadaConference Record of the 2006 IEEE Industry Applications Conference - Forty-First IAS Annual Meeting
Páginas2441-2446
Número de páginas6
Volumen5
DOI
EstadoPublicada - 2006
Evento2006 IEEE Industry Applications Conference - Forty-First IAS Annual Meeting - Tampa, FL, Estados Unidos
Duración: 8 oct 200612 oct 2006

Otros

Otros2006 IEEE Industry Applications Conference - Forty-First IAS Annual Meeting
País/TerritorioEstados Unidos
CiudadTampa, FL
Período8/10/0612/10/06

Áreas temáticas de ASJC Scopus

  • Ingeniería eléctrica y electrónica

Huella

Profundice en los temas de investigación de 'Direct torque control with reduced switching losses for asymmetric multilevel inverter fed induction motor drives'. En conjunto forman una huella única.