TY - JOUR
T1 - Absolute reliability and concurrent validity of hand-held dynamometry in shoulder rotator strength assessment
T2 - Systematic review and meta-analysis
AU - Chamorro, Claudio
AU - Arancibia, Miguel
AU - Trigo, Benjamín
AU - Arias-Poblete, Leónidas
AU - Jerez-Mayorga, Daniel
N1 - Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021/9
Y1 - 2021/9
N2 - The purpose of this study is to establish the absolute reliability between hand-held dynamometers (HHDs) and concurrent validity between HHDs and isokinetic dynamometers (IDs) in shoulder rotator strength assessment. The Medline, CINAHL, and Central databases were searched for relevant studies up to July 2020. Absolute reliability was determined by test–retest studies presenting standard error of measurement (SEM%) and/or minimal detectable change (MDC%) expressed as percentage of the mean. Studies considering intra-class correlation coefficient (ICC) between IDs and HHDs were considered for concurrent validity. The risk of bias and the methodological quality were evaluated according to COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN). Thirteen studies were included in the meta-analysis. Shoulder internal rotator strength assessment MDC% was 0.78%, 95% confidence interval (CI) −5.21 to 3.66, while shoulder external rotators MDC% was 3.29%, CI −2.69 to 9.27. ICC between devices was 0.94, CI (0.91 to 0.96) for shoulder internal rotators and 0.92, IC (0.88 to 0.97) for shoulder external rotators. Very high correlation was found for shoulder rotator torque assessment between HHDs and IDs. The COSMIN checklist classified the selected studies as adequate and inadequate.
AB - The purpose of this study is to establish the absolute reliability between hand-held dynamometers (HHDs) and concurrent validity between HHDs and isokinetic dynamometers (IDs) in shoulder rotator strength assessment. The Medline, CINAHL, and Central databases were searched for relevant studies up to July 2020. Absolute reliability was determined by test–retest studies presenting standard error of measurement (SEM%) and/or minimal detectable change (MDC%) expressed as percentage of the mean. Studies considering intra-class correlation coefficient (ICC) between IDs and HHDs were considered for concurrent validity. The risk of bias and the methodological quality were evaluated according to COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN). Thirteen studies were included in the meta-analysis. Shoulder internal rotator strength assessment MDC% was 0.78%, 95% confidence interval (CI) −5.21 to 3.66, while shoulder external rotators MDC% was 3.29%, CI −2.69 to 9.27. ICC between devices was 0.94, CI (0.91 to 0.96) for shoulder internal rotators and 0.92, IC (0.88 to 0.97) for shoulder external rotators. Very high correlation was found for shoulder rotator torque assessment between HHDs and IDs. The COSMIN checklist classified the selected studies as adequate and inadequate.
KW - Muscle strength
KW - Reliability
KW - Rotator cuff
UR - http://www.scopus.com/inward/record.url?scp=85114225699&partnerID=8YFLogxK
U2 - 10.3390/ijerph18179293
DO - 10.3390/ijerph18179293
M3 - Review article
AN - SCOPUS:85114225699
SN - 1661-7827
VL - 18
JO - International Journal of Environmental Research and Public Health
JF - International Journal of Environmental Research and Public Health
IS - 17
M1 - 9293
ER -