A decision algorithm to select a proper control method for a cascaded multilevel inverter under faulty condition

Saeed Ouni, Andres Ulloa Schmeisser, Mohammadreza Zolghadri, Hashem Oraee, Jose Rodriguez, Pablo Lezana

Resultado de la investigación: Conference contribution

3 Citas (Scopus)

Resumen

Fault tolerant ability is one of the most important tasks in high power converters. In this paper, a comparison between conventional fault tolerant methods is done for four applicable methods. For this purpose, their performance is investigated in specific case study and simulation results are used to illustrate their advantages and disadvantages. The most important features taken into account are maximum available voltage, harmonic distortion of output voltage and input current, and magnitude of common mode voltage. Finally, a decision algorithm based on the results is suggested to select suitable method to control inverter under specific faulty condition.

Idioma originalEnglish
Título de la publicación alojadaIECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society
EditorialInstitute of Electrical and Electronics Engineers Inc.
Páginas4830-4835
Número de páginas6
ISBN (versión digital)9781479917624
DOI
EstadoPublished - 25 ene 2016
Evento41st Annual Conference of the IEEE Industrial Electronics Society, IECON 2015 - Yokohama, Japan
Duración: 9 nov 201512 nov 2015

Other

Other41st Annual Conference of the IEEE Industrial Electronics Society, IECON 2015
PaísJapan
CiudadYokohama
Período9/11/1512/11/15

Huella dactilar

Electric potential
Harmonic distortion
Power converters

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Industrial and Manufacturing Engineering

Citar esto

Ouni, S., Schmeisser, A. U., Zolghadri, M., Oraee, H., Rodriguez, J., & Lezana, P. (2016). A decision algorithm to select a proper control method for a cascaded multilevel inverter under faulty condition. En IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society (pp. 4830-4835). [7392856] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/IECON.2015.7392856
Ouni, Saeed ; Schmeisser, Andres Ulloa ; Zolghadri, Mohammadreza ; Oraee, Hashem ; Rodriguez, Jose ; Lezana, Pablo. / A decision algorithm to select a proper control method for a cascaded multilevel inverter under faulty condition. IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society. Institute of Electrical and Electronics Engineers Inc., 2016. pp. 4830-4835
@inproceedings{a22a31772c4a4ac297a9296aa7bc178a,
title = "A decision algorithm to select a proper control method for a cascaded multilevel inverter under faulty condition",
abstract = "Fault tolerant ability is one of the most important tasks in high power converters. In this paper, a comparison between conventional fault tolerant methods is done for four applicable methods. For this purpose, their performance is investigated in specific case study and simulation results are used to illustrate their advantages and disadvantages. The most important features taken into account are maximum available voltage, harmonic distortion of output voltage and input current, and magnitude of common mode voltage. Finally, a decision algorithm based on the results is suggested to select suitable method to control inverter under specific faulty condition.",
keywords = "Cascaded H-Bridge Inverter, Fault Tolerant Ability, Neutral Shift Method, Peak Reduction",
author = "Saeed Ouni and Schmeisser, {Andres Ulloa} and Mohammadreza Zolghadri and Hashem Oraee and Jose Rodriguez and Pablo Lezana",
year = "2016",
month = "1",
day = "25",
doi = "10.1109/IECON.2015.7392856",
language = "English",
pages = "4830--4835",
booktitle = "IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

Ouni, S, Schmeisser, AU, Zolghadri, M, Oraee, H, Rodriguez, J & Lezana, P 2016, A decision algorithm to select a proper control method for a cascaded multilevel inverter under faulty condition. En IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society., 7392856, Institute of Electrical and Electronics Engineers Inc., pp. 4830-4835, 41st Annual Conference of the IEEE Industrial Electronics Society, IECON 2015, Yokohama, Japan, 9/11/15. https://doi.org/10.1109/IECON.2015.7392856

A decision algorithm to select a proper control method for a cascaded multilevel inverter under faulty condition. / Ouni, Saeed; Schmeisser, Andres Ulloa; Zolghadri, Mohammadreza; Oraee, Hashem; Rodriguez, Jose; Lezana, Pablo.

IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society. Institute of Electrical and Electronics Engineers Inc., 2016. p. 4830-4835 7392856.

Resultado de la investigación: Conference contribution

TY - GEN

T1 - A decision algorithm to select a proper control method for a cascaded multilevel inverter under faulty condition

AU - Ouni, Saeed

AU - Schmeisser, Andres Ulloa

AU - Zolghadri, Mohammadreza

AU - Oraee, Hashem

AU - Rodriguez, Jose

AU - Lezana, Pablo

PY - 2016/1/25

Y1 - 2016/1/25

N2 - Fault tolerant ability is one of the most important tasks in high power converters. In this paper, a comparison between conventional fault tolerant methods is done for four applicable methods. For this purpose, their performance is investigated in specific case study and simulation results are used to illustrate their advantages and disadvantages. The most important features taken into account are maximum available voltage, harmonic distortion of output voltage and input current, and magnitude of common mode voltage. Finally, a decision algorithm based on the results is suggested to select suitable method to control inverter under specific faulty condition.

AB - Fault tolerant ability is one of the most important tasks in high power converters. In this paper, a comparison between conventional fault tolerant methods is done for four applicable methods. For this purpose, their performance is investigated in specific case study and simulation results are used to illustrate their advantages and disadvantages. The most important features taken into account are maximum available voltage, harmonic distortion of output voltage and input current, and magnitude of common mode voltage. Finally, a decision algorithm based on the results is suggested to select suitable method to control inverter under specific faulty condition.

KW - Cascaded H-Bridge Inverter

KW - Fault Tolerant Ability

KW - Neutral Shift Method

KW - Peak Reduction

UR - http://www.scopus.com/inward/record.url?scp=84973165250&partnerID=8YFLogxK

U2 - 10.1109/IECON.2015.7392856

DO - 10.1109/IECON.2015.7392856

M3 - Conference contribution

AN - SCOPUS:84973165250

SP - 4830

EP - 4835

BT - IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society

PB - Institute of Electrical and Electronics Engineers Inc.

ER -

Ouni S, Schmeisser AU, Zolghadri M, Oraee H, Rodriguez J, Lezana P. A decision algorithm to select a proper control method for a cascaded multilevel inverter under faulty condition. En IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society. Institute of Electrical and Electronics Engineers Inc. 2016. p. 4830-4835. 7392856 https://doi.org/10.1109/IECON.2015.7392856