Diamond detectors for high energy physics experiments

L. Bäni, A. Alexopoulos, M. Artuso, F. Bachmair, M. Bartosik, J. Beacham, H. Beck, V. Bellini, V. Belyaev, B. Bentele, E. Berdermann, P. Bergonzo, A. Bes, J. M. Brom, M. Bruzzi, M. Cerv, G. Chiodini, D. Chren, V. Cindro, G. ClausJ. Collot, J. Cumalat, A. Dabrowski, R. D'Alessandro, D. Dauvergne, W. De Boer, C. Dorfer, M. Dünser, V. Eremin, R. Eusebi, G. Forcolin, J. Forneris, H. Frais-Kölbl, L. Gallin-Martel, M. L. Gallin-Martel, K. K. Gan, M. Gastal, C. Giroletti, M. Goffe, J. Goldstein, A. Golubev, A. Gorišek, E. Grigoriev, J. Grosse-Knetter, A. Grummer, B. Gui, M. Guthoff, I. Haughton, B. Hiti, D. Hits, M. Hoeferkamp, T. Hofmann, J. Hosslet, J. Y. Hostachy, F. Hügging, C. Hutton, H. Jansen, J. Janssen, H. Kagan, K. Kanxheri, G. Kasieczka, R. Kass, F. Kassel, M. Kis, V. Konovalov, G. Kramberger, S. Kuleshov, A. Lacoste, S. Lagomarsino, A. Lo Giudice, E. Lukosi, C. Maazouzi, I. Mandic, C. Mathieu, M. Menichelli, M. Mikuž, A. Morozzi, J. Moss, R. Mountain, S. Murphy, M. Muškinja, A. Oh, P. Oliviero, D. Passeri, H. Pernegger, R. Perrino, F. Picollo, M. Pomorski, R. Potenza, A. Quadt, A. Re, M. Reichmann, G. Riley, S. Roe, D. Sanz, M. Scaringella, D. Schaefer, C. J. Schmidt, S. Schnetzer, S. Sciortino, A. Scorzoni, S. Seidel, L. Servoli, S. Smith, B. Sopko, V. Sopko, S. Spagnolo, S. Spanier, K. Stenson, R. Stone, C. Sutera, B. Tannenwald, A. Taylor, M. Traeger, D. Tromson, W. Trischuk, C. Tuve, L. Uplegger, J. Velthuis, N. Venturi, E. Vittone, S. Wagner, R. Wallny, J. C. Wang, J. Weingarten, C. Weiss, T. Wengler, N. Wermes, M. Yamouni, M. Zavrtanik

Research output: Contribution to conferencePaper

6 Citations (Scopus)

Abstract

© 2018 IOP Publishing Ltd and Sissa Medialab. Beam test results of the radiation tolerance study of chemical vapour deposition (CVD) diamond against different particle species and energies is presented. We also present beam test results on the independence of signal size on incident particle rate in charged particle detectors based on un-irradiated and irradiated poly-crystalline CVD diamond over a range of particle fluxes from 2 kHz/cm2 to 10 MHz/cm2. The pulse height of the sensors was measured with readout electronics with a peaking time of 6 ns. In addition functionality of poly-crystalline CVD diamond 3D devices was demonstrated in beam tests and 3D diamond detectors are shown to be a promising technology for applications in future high luminosity experiments.
Original languageEnglish
DOIs
Publication statusPublished - 1 Jan 2018
Externally publishedYes
EventJournal of Instrumentation -
Duration: 1 Jan 2018 → …

Conference

ConferenceJournal of Instrumentation
Period1/01/18 → …

Fingerprint

Dive into the research topics of 'Diamond detectors for high energy physics experiments'. Together they form a unique fingerprint.

Cite this